Davis Construction: La Plata, MD
|
Location: |
La Plata, MD |
|
Climate Zone: |
Mixed Humid |
|
Subdivision: |
Washington Square (active adult community) |
|
Builder: |
Bruce Davis, Inc. |
Evaluation
Start Date: |
May 1999 |
|
Completion Date: |
September 2002 |
|
|
|
Objectives: |
To examine constructability, characteristics, and consumer acceptance of targeted technologies. |
|
General Construction Information: |
80-unit, age-restricted (55+) development, with 1 and 1½ story attached units. 1,000 to 1,500 square foot homes in the sale price range of $126,000 to $150,000. |
|
Significant Results: |
- Homebuyers were satisfied with the attributes of the technologies tested. Only the tubular skylights would not be included in their option purchase decisions.
- The builder chose to use two PATH technologies, fiber cement siding and tankless water heaters, as standard features in all homes. The other technologies are offered as options.
- The use of an ICF wall system does not guarantee a tight building. Air sealing details are still required in key areas.
- The tankless water heater with the 3.2 gallon per minute capacity (Seisco) met capacity needs at the project’s inlet water temperature of 73°F.
|
|