Asdal Builders: Henderson, NV

Summary
Details
Results
Journal
Resources

House Design

Three-bedroom, two-bath, 1,270-square foot home built in 1986 on uninsulated slab foundation. 2x4 wood-frame construction insulated with R-11 fiberglass batts, R-19 blown-in cellulose attic insulation, and stucco exterior finish. Double-glazed, aluminum windows cover 14 percent of wall area, heating and cooling equipment from 1986 (9.5 SEER air conditioner and 75 AFUE gas furnace).

Subject house

Subject house

Installation of Radiant Barrier

Installation of Radiant Barrier

Evaluation Methodology

  • Conduct energy audit including blower door and duct blaster tests
  • Interview occupants regarding energy use habits
  • Model the effect of potential energy retrofit measures using Energy-10 software
  • Select energy retrofit measures based on simple payback results of modeling
  • Monitor specific loads and ambient conditions using data logger. Monitor select appliance loads by a non-intrusive appliance load monitoring system mounted at the service entrance panel.

Additional Information
View evaluation results of this technology

Research Milestones

  • September to December 1999: Baseline monitoring prior to energy retrofitting
  • January 2000 through August 2000: Energy retrofit measures installed
  • September 2000 through April 2001: Post-retrofit energy monitoring
  • May 2002: Final report